Maytag MPE-33R Fireplace Specifications, Minimum Clearances To Combus- Tibles, Sides, Floor

Models: MPE-33R

1 20
Download 20 pages 60.42 Kb
Page 5
Image 5
MINIMUM CLEARANCES TO COMBUS- TIBLES

FIREPLACE SPECIFICATIONS

Cat. No. H3427

Model: MPE-33R

Description: Merit Plus Electric Fireplace, 33” Radiant

Shipping Weight: 81 lb.'s (36.75 KG) Packaging:

41” x 17 3/4” x 33 1/2”

(1040 mm x 451 mm x 850 mm)

14.1cu. ft.

Power Requirements: (120 Volt, 60 Hz.)

Rated Wattage - 1600 Watts Amperage - 13.33 Amps

(240 Volt, 60 Hz.)

Rated Wattage - 3000 Watts Amperage - 12.5 Amps

Blower CFM: 83 CFM

(120 V): 5,461 BTU/HR

(240 V): 10,239 BTU/HR

MINIMUM CLEARANCES TO COMBUS- TIBLES

This appliance is an electric fireplace designed to be framed in with combustible materials (up to the edge of the appliance). A drywall lip at the top of the fireplace and 4 nailing flanges on the sides of the appliance is provided to facilitate installation.

 

Clearances

 

 

 

Sides

 

0 inches - 0 mm

Floor

 

0 inches - 0 mm

Top

 

0 inches - 0 mm

Table 2

 

 

 

 

 

Mantel Clearance: Combustible and Non-com- bustible mantels may be installed at any height above the top of the face of fireplace.

Hearth Protection: A hearth is not mandatory, but it is recommended for aesthetic purposes. Secure the hearth extension to the floor to prevent possible shifting. Do no block the air- flow beneath the appliance (read the following WARNING).

Sides WARNING

This appliance is mounted on rubber feet to ensure adequate air circulation beneath fireplace. Do not block airflow at the bottom air intakes.

0 inches - 0 mm IMPORTANT

Cold climate installation recom- mendation: when installing this fireplace against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to appli- cable insulation codes.

Floor WARNING

To prevent contact with sag- ging or loose insulation, the appliance must not be installed againstvaporbarriersorexposed insulation. Localized overheat- ing could occur and a fire could result. Insulation and a vapor barrier should be placed a minimum of 2 inches from the appliance.

PRE-INSTALLATION

Before You Start

Check appliance for any concealed damage.

DETAILED INSTALLATION STEPS

1.Complete the framing opening to the dimen- sions specified in Figure 2.

2.Prepare the connections to power source: 120 Volt Connections - Locate the power cord on the left side of the unit and connect it to the outlet installed during the framing (see Figure 2). Verify that the power to the receptacle is off.

Hard wired installation:

Ensure that there is a minimum of 8" of the service cable for connection to the junction box on the fireplace.

-Loosen four screws to remove the junction box cover plate.

-Disconnect and remove the 120 Volt power cord from the fireplace wires.

-Position the fireplace into the framed-in opening. Attach fireplace to frame using nailing flanges provided.

-Complete the wiring to the fireplace as shown on Page 10.

-Place all wire connectors inside the junction box.

-Attach junction box cover plate with four screws.

240 Volt Connections - Ensure that there is a minimum of 8" of the service cable for connection to the junction box on the fireplace.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

-Loosen four screws to remove the junction box cover plate.

-Disconnect and remove the 120 Volt power cord from the fireplace wires.

-Position the fireplace into the framed-in opening. Attach fireplace to frame using nailing flanges provided.

-Complete the wiring to the fireplace as shown on Page 11.

-Place all wire connectors inside the junc- tion box.

-Attach junction box cover plate with four screws.

The fireplace wires L1, L2, N, N1, N2 and G are attached to the rear of the junction box cable clamp for easy access.

3.Wire a dedicated, properly fused circuit with an Amp rating for the appropriate voltage (120 V - 15 Amps or 240 V - 20 Amps). A dedicated circuit is required to prevent overloading a house circuit in cases of having multiple appliances on the same circuit. Use an outlet that is protected by a ground fault circuit interrupter where required by electrical code.

4.(If applicable) Make wall mount wall switch or wall thermostat connections as outlined on Pages 11 & 12.

5.Perform a function test. See Manual Control Panel Operation on Page 6 and Remote Control Operation on Page 7.

ELECTRICAL CONNECTIONS

Refer to the electrical diagrams on Pages 10 to 14.

PRE-INSTALLATION WARNING

Electrical wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to individuals.

DETAILED INSTALLATION STEPS IMPORTANT

Any electrical re-wiring of this appliance must be done by a qualified electrician.

ELECTRICAL CONNECTIONS WARNING

Do not use this fireplace if any part of it has been underwater. Immediately call a qualified service technician to inspect the fireplace and replace any part of the electrical system which has been under water.