Maytag MPE-33R Troubleshooting, Symptom, Who Performs, Corrective Action, Causes, Possible

Models: MPE-33R

1 20
Download 20 pages 60.42 Kb
Page 15
Image 15
TROUBLESHOOTING

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE

WHO PERFORMS

 

CORRECTIVE ACTION

 

 

 

 

CAUSES

CORRECTIVE ACTION

 

 

 

 

 

 

 

 

 

 

 

1. Fireplace turns off and

Fireplace has

Homeowner

The appliance is protected with a

 

 

 

will not turn on.

overheated.

 

 

safety device to prevent it from

 

 

 

 

 

 

 

 

overheating. If the fireplace should

 

 

 

 

 

 

 

 

overheat, a thermal switch will

 

 

 

 

 

 

 

 

disconnect power to the unit and

 

 

 

 

 

 

 

 

will not come back on without

 

 

 

 

 

 

 

 

being reset. Reset it by turning

 

 

 

 

 

 

 

 

the main power switch off and

 

 

 

 

 

 

 

 

waiting 5 minutes then turning it

 

 

 

 

 

 

 

 

back on.

 

 

 

 

 

 

 

 

 

 

2. Flame is fixed

Wiring may be loose

Qualified Service Technician

Inspect all wiring for loose

 

 

 

(unmoving).

or the flame motor

 

 

connections. If the wire

 

 

 

 

may be defective.

 

 

connections are good, replace the

 

 

 

 

 

 

 

 

flame motor.

 

 

 

 

 

 

 

 

 

 

3. Dim or poorly visible

Light bulb(s) burnt out

Homeowner

Inspect all wiring for loose

 

 

 

flame or log set and

or wiring is loose.

 

 

connections and repair or replace

 

 

 

ember is not glowing.

 

 

 

 

if necessary. Inspect light bulbs

 

 

 

 

 

 

 

 

and replace if necessary.

 

 

 

 

 

 

 

 

 

 

4. Flame sputters.

Flame motor is

Qualified Service Technician

Replace flame motor.

 

 

 

 

defective.

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Remote control does not

Low batteries.

Homeowner

Replace AA batteries in remote

 

 

 

work.

Unit switch and/or

 

 

control. If problem persists, there

 

 

 

 

 

 

may have been a loss of power to

 

 

 

 

wall switch in “ON”

 

 

 

 

 

 

 

 

the unit as a possible result from a

 

 

 

 

position.

 

 

 

 

 

 

 

 

power failure (i.e. breaker tripped).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn off main power on/off switch

 

 

 

 

 

 

 

 

(see Figure 4) and/or optional wall

 

 

 

 

 

 

 

 

switch (if applicable).

 

 

 

 

 

 

 

 

 

 

6. Circuit breaker trips or

Improper circuit

Qualified Service Technician

Check the house circuit to ensure

 

 

 

fuse blows when the unit

current rating.

 

 

it is on a dedicated circuit with

 

 

 

is turned on.

 

 

 

 

proper Amp. rating. If the circuit

 

 

 

 

 

 

 

 

breaker continues to trip (or blown

 

 

 

 

 

 

 

 

fuses), inspect wiring for a loose

 

 

 

 

 

 

 

 

connection or a dead short. Repair

 

 

 

 

 

 

 

 

or replace wiring and/or

 

 

 

 

 

 

 

 

connectors as necessary.

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 15
Image 15
Maytag MPE-33R warranty Troubleshooting, Symptom, Who Performs, Corrective Action, Causes, Possible