IMPORTANT SAFETY INSTRUCTIONS (cont.)
14.Once the unit is installed as outlined in the Installation Instructions, it is important that the fresh air supply is not obstructed. The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that the kitchen is
15.The flueway must also remain clear.
16.Storage cabinet area above the unit must be 36” (91.4 cm) and cannot project more than
13” (33.0 cm) outward from the rear wall. Beware of
potential hazards associated with retrieving items from such cabinets when the unit is in operation.
17. Keep area clean and free from combustible material,
gasoline, and other flammable liquids. | Flueway |
|
18.This appliance is not connected to a combustion products
evacuation device. It shall be installed and connected in accordance with current installation regulations giving particular attention to the relevant requirements regarding ventilation.
BASIC SPECIFICATIONS
| Description | VGWTO5240 |
|
|
|
| |
| Cutout Width | 24 3/4” (62.9 cm) |
|
|
|
| |
| Cutout Height | 10 1/4” (26.0 cm) |
|
|
|
| |
| Cutout Depth | Minimum - | 27 3/8” (69.5 cm) | Maximum - 27 7/8” (70.8 cm) | |||
| Overall Width | 26 1/4” (66.7 cm) |
|
|
|
| |
| Overall Height | To cooking surface - | 11 3/4” (29.8 cm) |
|
| ||
| from Bottom |
|
|
|
|
|
|
| Overall Depth | To end of side panel - |
| 28 5/8” (72.7 cm) | |||
| from Rear | To end of control panel - | 31” (78.7 cm) |
|
| ||
|
| To end of knobs - |
| 32 3/4” (83.2 cm) |
| ||
| Gas Requirements | Natural: | Standard residential 1/2” (1.3 cm) ID gas service line | ||||
|
| LP/Propane: | Standard residential 1/2” (1.3 cm) ID gas service line | ||||
|
|
| or |
|
|
|
|
|
|
| Equipped with high capacity hose/regulator for connection to a | ||||
|
|
| standard 20 lb. LP/Propane cylinder with Type 1, | ||||
|
| Unit must be ordered Natural or LP/Propane - Unit is not field convertible | |||||
| Maximum amp usage | .08 amps |
|
|
|
|
|
| Burner Rating | 27,500 BTU NAT./27,500 BTU LP/Propane |
|
| |||
| Approximate |
|
|
|
|
|
|
| Shipping Weight | 160 lbs. (72.0 kg) |
|
|
|
| |
|
|
|
|
|
|
|
|
CABINET CUTOUT DIMENSIONS
10 1/4” (26.0 cm)
27 3/8”
(69.5 cm) Min. 24 3/4”
(62.9 cm)
6” (15.24 cm)
to side wall
3/4” Min. (1.9 cm)
PROXIMITY TO CABINET INSTALLATION
The unit may be installed directly adjacent to the existing base cabinets. IMPORTANT - The side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. There is a 0” side and rear clearance to
4 | 5 |