Electronic Control Center
|
|
| UPPER | MIDDLE | LOWER |
|
|
|
TriTemp™ Wine Storage | ZONE | LOWER |
|
| LIGHTS | DISPLAY | ALARM | Three Independent Temperature Areas |
150 Bottle Capacity | HIGHER |
| Electronic Control Center | |||||
|
|
|
|
| ||||
|
| TEMP | TEMP |
|
|
|
|
|
Electronic Control Center | Alarm |
Product Controls
With the TriTemp™ Storage System, you can set the temperature in each of the three zones within a range of 43°F to 65°F (6°C to 18°C). The unit is factory set at 43° F (6°C) in the top two zones and 55°F (13°C) in the bottom zone. Select the zone you wish to adjust by pressing the "ZONE" key. The lighted bar on the control center will toggle between the upper, middle, and lower zones. When the bar above the zone you wish to adjust is lit, press the lower temp or higher temp key to select the desired temperature. The set temperature will flash on the control center. After 7 seconds, the temperature displayed will revert to the ACTUAL zone temperature and will no longer flash. Toagain view the set temperature, press the "ZONE" key. Refer to the Wine Storage Guidelines section and the Suggested Serving Temperatures section.
Lower Temp
The lower temp key allows you to decrease the temperature in the selected zone in one degree increments.
Higher Temp
The higher temp key allows you to increase the temperature in the selected zone by one degree increments.
Lights
The lights key allows you to turn the lighting on independent of the door opening for displaying the contents of the upper and middle zones. To turn the lights on, press the button once. Lights should not be left on for extended periods of time, as long term light exposure will affect the quality of your wine.
Display
The display key will turn the power to the display off. Press this button if you do not wish for the control panel to be illuminated. To turn the display on, press the display key.
Your wine cellar is equipped with two alarms: High Temperature alarm and Open Door alarm. The High Temperature alarm will signal if the temperature in any zone fluctuates 5 degrees from your set point for an extended period of time. To set this alarm, press and hold the alarm key for two seconds. A bell will appear on the display when the alarm has b een successfully enabled. When the alarm is trigg ered, a beeping noise will be heard and the wine cellar’s display will flash and show an alarm message. To turn the alarm off, press the alarm key. To completely disengage the alarm, press and hold the alarm key for two seconds. The Open Door alarm is set automatically. The Open Door alarm will signal if the wine cellar’s door has been left open for three minutes. A beeping noise will be heard and an alarm message will appear on the display. The wine cellar’s door must be closed in order to turn the alarm off.
Temperature Unit Conversion
Your wine cellar is factory set to display degrees Farenheit. If you prefer Celsius, press and hold the alarm key and display key for 5 second s.
Holiday Mode for Sabbath Observance
Pressing and holding the display button continuously for 10 seconds accesses this mode. The display will continue to be on as long as the button is pressed and at the end of 10 seconds, the display will turn off and holiday mode will be engaged. NOTE: To enter Holiday Mode, the display must be on prior to initiating the Holiday Mode. To cancel Holiday Mode, press and hold the display button continuously for 10 seconds. At the end of 10 seconds the display will turn on. When Holiday Mode is selected: a random time delay will be applied to the compressor relay start and stop. The chamber lights relay will remain
Product Controls
12 | 13 |