VGBQ410-3RT/E*

T-Series/E-Series
Three-Burner All-Grill

VGIQ412-2RT*

T-SeriesTwo-BurnerGrill

w/SideBurners

(inc.TruSear™ Burner)

VGBQ412-2RT/E*

T-Series/E-Series
Two-BurnerGrill
w/Side Burners

VGIQ410-3RT/E*

T-Series/E-Series
Three-Burner All-Grill
(inc. TruSear™Burner)
GAS
Fixed piping installations
•Check with localgas utility
companyor with local codes
forinstructions on installing
gassupply lines. All gas
connectionsshould be made
bya competent technician and
inaccordance with local codes
andor ordinances. In the
absenceof codes, the
installationmust comply with
theNational Fuel Gas Code
ANSIZ223.1.
•An installer-supplied gas shut-
offvalve must be installed in
aneasily accessible location.
Allinstaller-supplied parts
mustconform to local codes.
•Must be isolatedfrom the gas
supplypiping system by
closingits individual manual
shut-offvalve during any
pressuretesting of that system
attest pressures equal to or
lessthan 1/2 psi (3.5 kPa).
Natural gas models
Watercolumn pressure
oOperating pressure—4.0"
WCP
oSupply pressure of 6" – 14"
WCP
oIf incoming pressure exceeds
14"WCP, a step-down
regulatoris required.
Acceptsstandard residential
1/2”(1.3 cm) ID gas service
line;1/2” (1.3 cm) NPT male
with7/8” (2.2 cm) flare adapter.
oIf using a Viking GSH12
flexiblehose, remove the
1/2”(1.3 cm) flare adapter
andattach hose to the 7/8”
(2.2cm) male flare on the
regulatorassembly.
LP/propanemodels
Watercolumn pressure
oOperating pressure—10” WCP
oSupply pressure of 11” – 14”
WCP(for fixed piping
installations)
oIf incoming pressureexceeds
14”WCP, a step-down
regulatoris required.
Acceptsstandard residential
1/2”(1.3 cm) ID gas service
line;1/2” (1.3 cm) NPT male
with3/8” (0.95) flare adapter.
LP/propanetank installations
Watercolumn pressure
oOperating pressure—10”
WCP
Includeshigh-capacity
hose/regulatorassembly for
connectionto a standard 5-
gal./20-lb.(approx. 12”
diameter/18”H.)LP/propane
gascylinder equipped with a
Type1, QCC-1 connector
oThe cylinder connection
devicemust be compatible
withthe Type 1, QCC-1
connectoron the outdoor
cookingappliance.
oThe cylinder must be
providedwith a shut-off
valveterminating in an
LP/propanegas supply
cylindervalve outlet
specified.
oThe cylinder supplysystem
mustbe arranged for vapor
withdrawaland provided with
alisted OPD (overfilling
preventiondevice).
ELECTRICAL
T-Seriesmodels
o9-volt DC battery for
electronicignition
o2’ (61.0 cm) powercord
supplycord with 3-prong
groundedplug attached to
rotisseriemotor.
120VAC/60 Hz
oRotisserie motor max. amp
usage—6.0
E-Seriesmodels
o3’ (91.4 cm) powercord
supplycord with 3-prong
groundedplug attached to
grill
120VAC/60 Hz
o120 VAC/60 Hz
oGrill max. amp usage
VGBQ/VGIQ410—2.2
VGBQ/VGIQ412—2.3
o2’ (61.0 cm) powercord
supplycord with 3-prong
groundedplug attached to
rotisseriemotor.
120VAC/60 Hz
oRotisserie motor max. amp
usage—6.0
PLUMBING
Notapplicable

UTILI TY

REQUIREMENTS
OUTD OOR—C OOKING

41”W. Ul tra-Pre mium T-Seri es/E-Se ries Gas Gr ill

PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
REL E A S E D 05 / 1 2 / 0 8
©20 0 7 VR C — INFORMATION SUBJECT TOCHANGE
Installation Requirements
VGBQ410-3RT VGBQ412-2RT/E VGIQ410-3RT/E VGIQ412-2RT
Burnerrating
StandardSS grill burners (each) 25,000BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP
Smokerburner (split standard) 12,500BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP
GourmetGlo™rotisserie burner 15,000BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
Sidegrill burners (each) 15,000BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
TruSearinfrared burner
3
0,000BTU (8.8 kW) Nat./LP
3
0,000BTU (8.8 kW) Nat./LP