Viking VGSB241T, VGSB244T, VGSB152T manual Installation Requirements, Outdoor-Cooking, Utility

Models: VGSB152T VGSB244T VGSB241T

1 7
Download 7 pages 6.03 Kb
Page 6
Image 6
Installation Requirements

OUTDOOR—COOKING

Built-In Gas Side Burner, 24”W. Rangetop,

Wok/Cooker, & TruSearInfrared Grillers

Installation Requirements

VGSB152T

VGRT244T

VGWT241T

VGIB151T

VGIB242T

Double Side Burner

24”W. Rangetop

24”W. Wok/Cooker

15”W. TruSear

24”W. TruSear

 

 

 

Infrared Griller

Infrared Griller

 

 

 

 

 

 

 

UTILITY

 

 

 

 

REQUIREMENTS

 

 

 

 

 

 

 

GAS

Burner rating

VGSB152T—Two grated burners @ 15,000 BTU (4.4 kW) Nat./13,500 BTU LP (4.0 kW)

VGRT244T—Four grated burners @ 15,000 BTU (4.4 kW) Nat./13,500 BTU LP (4.0 kW)

VGWT241T—One grated burner @ 27,500 BTU (8.1 kW) Nat./LP

VGIB151T—One infrared grill burner @ 21,500 BTU (6.3 kW) Nat./20,000 BTU (5.9 kW) LP

VGIB242T—Two infrared grill burners, each @ 21,500 BTU (6.3 kW) Nat./20,000 BTU (5.9 kW) LP

Fixed piping installations

o Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.

o An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes.

o Must be isolated from the gas supply piping system by closing its individual manual

shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa).

Natural gas models (and LP/propane, for VGWT only) o Water column pressure

Operating pressure—4.0”

WCP

Supply pressure of 6” – 14” WCP

If incoming pressure exceeds 14” WCP, a step- down regulator is required.

o Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 7/8” (2.2 cm) flare adapter.

o If using a Viking GSH12 flexible hose, remove the 1/2” (1.3 cm) flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.

LP/propane models

o Water column pressure

Operating pressure—10”

WCP

Supply pressure of 11” – 14” WCP (for fixed piping installations)

If incoming pressure exceeds 14” WCP, a step- down regulator is required.

o Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 3/8” (0.95) flare adapter.

LP/propane tank installations o Water column pressure

Operating pressure—10”

WCP

o Includes high-capacity hose/regulator assembly for connection to a standard 5- gal./20-lb. (approx. 12” diameter/18”H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector

The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance.

The cylinder must be

provided with a shut- off valve terminating in an LP/propane gas supply cylinder valve outlet specified.

The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device).

ELECTRICAL

9-volt DC battery for electronic ignition (not included?)

Max. amp usage o VGWT—0.08

PLUMBING

Not applicable

P L A N N I N G A N D D E S I G N G U I D E

R E L E A S E D 1 2 / 1 / 0 7

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

Page 6
Image 6
Viking VGSB241T, VGSB244T Installation Requirements, Outdoor-Cooking, Built-InGas Side Burner, 24”W. Rangetop, Utility