VENTILATION

Built-In Island/Classic Chimney Island Hood

Installation Requirements

VIH Professional

VCIH Professional Classic

DCIH Designer Chimney

Island Hood

Chimney Island Hood

Island Hood

 

 

 

 

UTILITY REQUIREMENTS

 

 

 

 

Proper installation/ducting is extremely important to ensure maximum performance. Use a qualified and trained installer.

DUCTING

Check with a qualified and trained installer or local codes for makeup air requirements, if any.

Max. duct run

o For 300 – 1,200 CFM—50’ (152.4 m)

o For 1,500 CFM—75’ (22.9 m) o Duct run length is for general reference only; for longer

duct runs, increase duct size and contact a qualified and trained installer.

o Straight runs and gradual turns are best; for example, each 90° elbow is equivalent to 5’ – 10’ (1.52 – 3.05 cm) of straight run.

7” (17.8 cm) round duct for 300 – 600 CFM; 10” for 900 – 1500 CFM

o Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.

GAS

Not applicable

ELECTRICAL

Hardwire direct with two-wire with ground

120 VAC/60 Hz

Max. amp usage (rating includes rec. ventilator kit rating)

PLUMBING

Not applicable

Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly overstated.

Model

Ventilator Kits

Interior Exterior

Duct Size

Interior Exterior

Max. Amps

Interior Exterior

VIH3608

VIV600/1200*

VEV900/1200*

7” (17.8 cm)/

10” (25.4 cm)

4.9/7.4

7.4/4.7

 

 

 

10” (25.4 cm)

 

 

 

VIH4208

VIV600/1200*

VEV900/1200/1500*

7” (17.8 cm)/

10” (25.4 cm)

4.9/7.4

7.4/4.7/5.5

 

 

 

10” (25.4 cm)

 

 

 

VIH5408

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

8.2

5.5/6.2

VIH6608

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

8.2

5.5/6.2

VCIH3608

DIV600*

DEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

3.9

6.6/3.9

VCIH4208

DIV600*

DEV900/1200/1500*

7” (17.8 cm)

10” (25.4 cm)

4.7

7.4/4.8/5.5

VCIH5408

DIV1200*

DEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

8.6

5.6/6.4

VCIH6608

DIV1200*

DEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

9.5

6.5/7.3

DCIH3604

DIV600

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

4.7

8.6

DCIH4204

DIV600

DEV1200/DEV1500**

7” (17.8 cm)

10” (25.4 cm)

4.7

7.4/4.7/5.5

DCIH5404

DIV1200*

DEV1200/DEV1500**

10” (25.4 cm)

10” (25.4 cm)

8.6

5.6/6.4

*A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

**It is recommended that the 1,500 CFM ventilator be used with longer duct runs.

Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.