Vinotemp VINO-1500SS, VINO-1900SS manual Condensing Unit Troubleshooting, Unit not running

Models: VINO-1500SS VINO-1900SS

1 5
Download 5 pages 60.42 Kb
Page 5
Image 5
8. Condensing Unit Troubleshooting

8. Condensing Unit Troubleshooting

Unit not running

a.

Incorrect power supply

a.

Check for proper voltage

b.

Incorrect or loose wirings

b.

Check all wirings and connections

c.

Failed components

c.

Check start relay, start capacitor, overload

 

 

 

protector, compressor.

d.

Liquid refrigerant in the compressor

d.

Call service for OEM information

e.

Low pressure switch shutting down the system

e.

Check for system restriction or low

 

 

 

refrigerant

- 4 -