Vinotemp WM-150SCU 3 Digital Controller, LED & Display Messages, Use of the Digital Controller

Models: VINO-1500SSL VINO-2500SSL WM-650SCU WM-450SCU WM-15SFCL WM150-450SCU WM-25SFCL WM-250SCU WM-150SCU WM-45SFCL WM-65SFCL VINO-4500SSL VINO-6500SSL

1 25
Download 25 pages 7.58 Kb
Page 17
Image 17
5) LED & Display Messages

If the function is enabled, the compressor is not energized for three minutes after controller power up.

The function is also active in hot-gas defrost mode.

5) LED & Display Messages

1.

LED off

1.

Compressor and defrost deactivated

2.

LED on

2.

Compressor energized

3.

LED blinking 0.5s on/0.5s off

3.

Defrost activated

4.

LED blinking 0.5s on/1.5s off

4.

Sensor fault

5.

Display A1

5.

Regulation probe fault

6.

Display A2

6.

Defrost probe fault

3. Use of the Digital Controller

Fig. 3.3 Digital Controller

1) Display

During normal operating conditions, the display shows the value measured by the air regulation probe. In case of active alarm, the temperature flashes alternately to the code alarm.

1.1 LED Functions

1.2 Front Panel Commands

- 16 -

Page 17
Image 17
Vinotemp WM-150SCU, VINO-6500SSL, VINO-4500SSL 3 Digital Controller, LED & Display Messages, Use of the Digital Controller