3. Air Sensor

Supply and return air flow from the evaporator unit shall be unobstructed for at least 1 foot.

There is a gravity drain line so that it can not be installed above the evaporator unit. Otherwise a condensation pump must be used.

3. Air Sensor

The air sensor can be located in the wine room or the return air area, but not the supply air area.

4. Refrigeration Piping and Charging

NOTES: ALWAYS USE THE SUPERHEAT AND SUBCOOLING, PRESSURE READINGS TO CHARGE REFRIGERANT PROPERLY, THE LISTED CHARGES ARE FOR REFERENCE ONLY.

The installation order starts from condensing unit (including the receiver), liquid line filter-drier, moisture-liquid indicator (sight glass), liquid line, evaporator unit (including liquid line solenoid valve and thermostatic expansion valve or automatic expansion valve), suction line, and returning to condensing unit.

The subcooling at the condensing unit shall be around 10° F. The charge may be complete when there are no more bubbles forming in the sight glass.

The evaporator’s constant pressure expansion valve is set around 38- 40°F at factory. This pressure setting gives a dew point to maintain the humidity for storing wine.

The superheat at the evaporator unit shall be around 9-18°F under low and high load at 75°F ambient temperature.

Low side pressure: 33 psig

High side pressure: 130 -150 psig at 75 -90 °F ambient temperatures

The line sizes and refrigerant charges are listed as follows.

MODEL

REFRIGERATION

LIQUID

SUCTION

LINES

LINE

LINE

 

VINO-

< 50 FT

1/4"

3/8” OD

2500SSR

OD

 

 

VINO-

< 50 FT

1/4"

1/2” OD

4500SSR

OD

 

 

VINO-

< 50 FT

1/4"

5/8” OD

6500SSR

OD

 

 

DRAIN

LINE

1/2” OD

1/2” OD

1/2” OD

CHARGE

R134a/

20OZ R134a/

26OZ R134a/

32OZ