Vinotemp VINO4500HZD, VINO6500HZD 7 CABINET GRILLE, VINO3500-8500HZDTHROUGH WALL INSTALLATION

Models: VINO6500HZD VINO4500HZD

1 25
Download 25 pages 29.42 Kb
Page 10
Image 10
Fig. 2.7 CABINET GRILLE

Fig. 2.7 CABINET GRILLE

2. VINO3500-8500HZD THROUGH WALL INSTALLATION

1.Cut a rectangular opening at the wine room wall as illustrated. The dimensions of the opening shall be 1/4” larger than the width and height of the unit.

2.If top exhaust, cut another rectangular opening at the top of the cabinet to the length and width of the top exhaust.

3.Construct a shelf as shown. The shelf must be capable of supporting the weight of the unit.

4.Place the unit on the shelf with the back of unit flush with the outside of the wall.

5.Attach the grille to the outside wall with screws.

6.Seal the area between the cooling unit and opening with a high quality weather stripping or polyurethane spray foam and cover with molding.

7.If top exhaust, place another gaskets along the top exhaust at the top of the cooling unit (see Fig.2.9).

8.Attach the molding to the wall not the unit.

9.Plug the unit into a properly grounded and dedicated outlet of adequate capacity.

-9 -