f.

Refrigerant low or leaking

 

f.

Check for current and sealed

 

 

 

 

 

system leakage

 

g.

Capillary tube blockage

 

g.

Check for low side pressure

11.Water leak

a. High humidity

 

a. Use drain line

 

b. Air leak in wine cellar

 

b. Check for any air leak

 

c. Evaporator air flow restriction

 

c. Check air flow or air TD crossing

 

 

 

 

 

evaporator

 

d. Water passages restricted

 

d. Clean the drip tray

 

e. Drip tray leak

 

e. No water overflow but leak

12.Circuit

a.

Incorrect fuse or breaker

 

a.

Check for proper fuse or breaker

tripping

b.

Incorrect wirings

 

b.

Check for wirings and connections

 

c.

Failed components

 

c.

Call service

 

 

 

 

 

 

13.Noisy

a.

Mounting area not firm

 

a.

Add support to improve installation

operation

b.

Loose parts

 

b.

Check fan blades, bearings, cabinet

 

 

 

 

 

washers, tubing contact and loose

 

 

 

 

 

screws.

 

c.

Compressor overloaded due

to

c.

Check for airflow blockage

 

 

high ambient temperatures

or

 

 

 

 

airflow restriction

 

 

 

 

d.

Malfunctioning components

 

d.

Call service for checking internal

 

 

 

 

 

loose, inadequate lubrication and

 

 

 

 

 

incorrect wirings

 

 

 

 

 

 

- 19 -

Page 20
Image 20