If the function is enabled, the compressor is not energized for three minutes after controller power up.
The function is also active in
5) LED & Display Messages
1. | LED off | 1. | Compressor and defrost deactivated |
2. | LED on | 2. | Compressor energized |
3. | LED blinking 0.5s on/0.5s off | 3. | Defrost activated |
4. | LED blinking 0.5s on/1.5s off | 4. | Sensor fault |
5. | Display A1 | 5. | Regulation probe fault |
6. | Display A2 | 6. | Defrost probe fault |
3. Use of the Digital Controller
Fig. 3.3 Digital Temperature Controller
1) Display
During normal operating conditions, the display shows the value measured by the air regulation probe. In case of active alarm, the temperature flashes alternately to the code alarm.
1.1 LED Functions
1.2 Front Panel Commands
- 10 -