Vinotemp WM-1500-HTD, VINO8500HZD, WM-8500HTD, VINO3500HZD, VINO2500HZD, VINO1500HZD 6. “HA” alarm

Models: VINO1500HZD VINO2500HZD VINO3500HZD WM-8500HTD WM-1500-HTD VINO8500HZD

1 25
Download 25 pages 30.94 Kb
Page 19
Image 19
6. “HA” alarm

6. “HA” alarm

a.

Improper room insulation & seal

a.

Check for insulation, gasket and

blinking and

b.

Room too large

 

 

b.

door opening

 

 

 

beeping,

 

 

Check for excessive size

 

c.

Ambient temperature too high

 

c.

Check for installation location

 

temperature

 

 

d.

Exhaust restricted

 

 

d.

Leave minimum 3 feet clearance for

high or not

 

 

 

 

 

 

the exhaust side and leave

cooling and

 

 

 

 

 

 

minimum 1 foot clearance for the

running

e.

Malfunctioning fans

 

 

e.

fresh air intake side

 

 

 

continually

 

 

Check for both evaporator and

 

 

 

 

 

 

condenser fans

 

 

 

 

f.

Improper

evaporator

or

f.

Check for air restrictions

 

 

 

condenser airflow

 

 

g.

Clean condenser

 

 

 

 

g.

Dirty Condenser

 

 

 

 

 

 

h.

Iced evaporator

 

 

h.

Defrost and reset temperature

 

 

i.

Refrigeration system restriction

i.

Call

service

for

checking

 

 

 

 

 

 

 

restrictions

 

 

 

 

j.

Refrigerant leak

 

 

j.

Call service for checking loss of

 

 

 

 

 

 

 

refrigerant

 

 

 

 

k.

Undercharge or overcharge

 

k.

Call service to add or remove

 

 

 

 

 

 

 

refrigerant

 

 

 

 

l.

Failed components

 

 

l.

Check

compressor

windings,

start

 

 

 

 

 

 

 

relay and overload protector

 

 

 

 

 

 

 

7.Unit running

a. Improper room insulation & seal

a. Check

for insulation,

gasket

and

too long

b. Exhaust restricted

 

 

 

door opening

 

 

 

 

 

 

b. Leave minimum 3 feet clearance for

 

 

 

 

 

 

 

the exhaust side and leave minimum

 

 

 

 

 

 

 

1 foot clearance for the fresh air

 

 

 

 

 

 

 

intake side

 

 

 

 

c. Room too large

 

 

c. Check for excessive size or increase

 

 

 

 

 

 

 

setting

 

 

 

 

 

d. Ambient

temperature

higher

>

d. Check

for installation

location or

 

 

90°F

 

 

 

 

increase setting

 

 

 

 

e. Dirty Condenser

 

 

e. Clean condenser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.Fan motor

a.

Post-compressor fan running

a.

Check for fan running time FON

running but

b.

mode

 

 

 

b.

Check for proper voltage

 

compressor

Incorrect power supply

 

 

 

c.

Incorrect or loose wirings

 

c.

Check all wirings and connections

not running

 

d.

Failed components

 

 

d.

Check start relay, start capacitor,

 

 

 

 

 

 

 

overload protector, compressor.

 

e.

Liquid

refrigerant

in

the

e.

Call service for OEM information.

 

 

compressor

 

 

 

 

 

 

 

 

9.Compressor

a.

Fan blade stuck

 

 

a.

Check for proper clearance

 

running but

b.

Incorrect or loose wirings

 

b.

Check all wirings

 

 

 

fan not

c.

Failed motors

 

 

c.

Call service for checking open or

 

 

 

 

 

 

shorted windings

 

 

 

running

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.Evaporator

a.

Evaporator air flow restriction

 

a.

Check for fans

 

 

 

Icing

b.

Not stopping due to air leak, high

b.

Check for seal, door opening,

 

 

ambient

temperature

or low

 

ambient temperature and setting

 

 

setting

 

 

 

 

 

 

 

 

 

 

c.

Low ambient temperature

 

c.

Defrost unit

 

 

 

 

d.

Bad thermostat or sensor

 

d.

Check for thermostat and sensor

 

e.

Moisture in the system

 

 

e.

Working initially then stopping

 

- 18 -

Page 19
Image 19
Vinotemp WM-1500-HTD, VINO8500HZD, WM-8500HTD, VINO3500HZD, VINO2500HZD, VINO1500HZD manual 6. “HA” alarm