2) Alarm Signals

2) Alarm Signals

2.1 Code Description

2.2 Alarm Recovery

Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as soon as the temperature returns to normal value. Alarm “CA” (with i1F=PAL) recovers only by switching off and on the instrument.

3) Temperature Set-Point

3.1 How to see the set-point

1.Push and immediately release the SET key: the display will show the Set-point value;

2.Push and immediately release the SET key or wait for 5 seconds to display the probe value again.