Viper FANG 18C user manual Cause, Solution

Models: FANG 18C

1 16
Download 16 pages 11.05 Kb
Page 15
Image 15
CAUSE

 

ENGLISH

 

USER MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

PROBLEM

 

CAUSE

SOLUTION

 

 

 

 

 

 

 

 

The wiring not connected

Check the wiring or contact Viper

 

 

 

correctly or bad wiring

Distributor

 

 

No Power

 

 

 

 

 

Bad brush motor

Contact Viper Distributor

 

 

 

 

 

 

 

 

 

 

 

Carbon brushes worn out

Contact Viper Distributor

 

 

 

 

 

 

 

Vacuum

The wiring not connected

Check the wiring or contact Viper

 

 

correctly or bad wiring

Distributor

 

 

motor does

 

 

 

 

 

Bad vacuum motor

Contact Viper Distributor

 

 

not run

 

 

Carbon brushes worn out

Contact Viper Distributor

 

 

 

 

 

 

 

 

 

 

 

Bad ball valve

Contact Viper Distributor

 

 

Little or no

Bad solution valve

Contact Viper Distributor

 

 

solution flow

Ball valve position in need of

When ball valve is in horizontal position.

 

 

 

adjustment

The amount of solution flow is maximum.

 

 

 

Squeegee clogged

Clean debris off squeegee with damp

 

 

 

towel

 

 

 

 

 

 

 

 

Squeegee blades worn

Install new squeegee blades

 

 

 

 

 

 

 

 

 

 

 

Confirm that the squeegee assembly is

 

 

Squeegee not mounted correctly

securely fastened to the machine and not

 

 

 

 

 

loose fitting

 

 

 

Vacuum hoses have a hole or are

Check hose connections and make sure

 

 

 

loose

they are firm. Replace hose if damaged.

 

 

Poor water

Vacuum hose may be clogged

Check hose for debris and remove any

 

 

clog.

 

 

pick up

 

 

 

 

Drain hose stopper is loose

Tighten drain plug.

 

 

 

 

 

 

Vacuum motor is loose

Tighten vacuum motor mounting screws.

 

 

 

Do not over tighten or damage will occur.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery tank lid is loose

Confirm the clear recovery tank lid is

 

 

 

securely in place.

 

 

 

 

 

 

 

 

Recovery tank is full

Drain recovery tank

 

 

 

 

 

 

 

 

 

Float shut off is clogged

Remove float shut off from inside recovery

 

 

 

tank and remove any debris

 

 

 

 

 

 

14

FANG 18C

80188EU(1)2009-01

Page 15
Image 15