Viper GTR1500-EU Machine Storage, Troubleshooting Machine Does Not Operate, Poor Brush Pickup

Models: GTR1500-EU

1 12
Download 12 pages 6 Kb
Page 12
Image 12
MACHINE STORAGE

USER MANUAL

ENGLISH

6)Check vacuum hose for holes and clogs. If either is found, replace hose immediately.

7)Lubricate wheels with a water resistant lubricant on a monthly basis.

8)Check machine for loose or missing nuts, screw and bolts and replace as necessary.

MACHINE STORAGE

1)Unplug machine from power source

2)Store machine in upright position in a dry area

TROUBLESHOOTING

MACHINE DOES NOT OPERATE

Bad power cord

oMay need to be replaced

Bad on/off switch

oMay need to be replaced

Poor wiring

oContact Service Center

Defective vacuum motor

oContact service center

Work carbon brushes in vacuum motor

oContact service center

POOR BRUSH PICKUP

Worn brush assembly

oReplace brush assembly

Debris caught in brush

oRemove clogged debris

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

POOR VACUUM PERFORMANCE

Filter bag is full

oReplace filter bag

Clogged hose

oRemove obstruction

Clogged extension wand

oRemove obstruction

Defective vacuum hose

oReplace hose

Loose vacuum hose connections

oCheck and tighten all hose connections

Front cover loose

oCheck and secure front bag cover housing