VIVOTEK
User's Manual - 171
trigger boot,
di,
motion,
seq,
recnotify,
tampering,
visignal,
vi
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
triggerstatus String[40] trigger 6/6 The status for event trigger
exttriggerstatus trigger,
normal_trigger
,
trigger_normal
<blank> 6/6 The status for event DI 1 trigger
exttriggerstatus1 trigger,
normal_trigger
,
trigger_normal
<blank> 6/6 The status for event DI 2 trigger
exttriggerstatus2 trigger,
normal_trigger
,
trigger_normal
<blank> 6/6 The status for event DI 3 trigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and
3rd windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.