Syntax:

http://<servername>/cgi-bin/setdo.cgi?do1=<state>[&do2=<state>] [&do3=<state>][&do4=<state>][&return=<return page>]

Where state is H, L. H means NC (normal close) connected with COMMON and L means NO (normal open) connected with COMMON. The number of DO dependents on the server type.

parameter

Value

description

 

 

 

do<num>

<state>

H – NC connected with COMMON

 

 

L – NO connected with COMMON

 

 

 

return

<return page>

Redirect to the page <return page> after the

 

 

parameter is assigned. The <return page> can

 

 

be a full URL path or relative path according the

 

 

the current path. If you omit this parameter, it

 

 

will redirect to an empty page.

 

 

 

Example: Drive the digital output 1 to high and redirect to an empty page

http://myserver/cgi-bin/setdo.cgi?do1=H

Query status of the digital input

Note: This request requires the privilege of I/O access control.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4]

If no parameter is specified, all the status of digital input will be returned.

Return:

- 79 -

www.vivotek.com

T: 886-2-82455282

F: 886-2-82455532

Page 83
Image 83
Vivotek FD6121 manual Query status of the digital input