- 84 -
www.vivotek.com
(get/set)
name string[40] 6/6 The identification of this entry
enable 0, 1 6/6 To enable or disable this event.
priority 0, 1, 2 6/6 Indicate the priority of this event.
“0” indicates low priority.
“1” indicates normal priority.
“2” indicates high priority.
delay 1~999 6/6 Delay seconds before detect next
event.
trigger boot,
di,
motion,
seq,
6/6 Indicate the trigger condition.
“boot” indicates system boot.
“di” indicates digital input.
“motion” indicates video motion
detection.
“seq” indicates periodic condition.
di <integer> 6/6 Indicate which di detected.
T
his field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin <integer> 6/6 Indicate which motion detection
windows detected.
T
his field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and 3rd
windows, set mdwin as 5.
inter 1~999 6/6 Interval of period snapshot in minute.
T
his field is used when trigger
condition is “seq”.
User's Manual - 93