3. PRECAUTIONS FOR INSTALLATION OF CCU-11B.

Please read following instructions carefully to ensure proper operation of the CCU-11B.

1.Be careful about damage by static electricity as the CCU-11B incorporates CMOS IC's. Do not touch com- ponents and connectors.

2.Turn off the AC power switch when you take out or insert the CCU-11B unit or any other unit.

3.Always insert the CCU-11B unit into the "CCU" slot. Otherwise, there is a danger that the unit will be damaged.

4.Make sure mini-jumper for battery back-up is always placed in "ON" position each time it is used.

5.Incorrect setting of function select switches may lead to incorrect performance.

6. Even if you do not need programming functions, be

sure to carry out initial programming and registration

at station No. 11 when you install the new unit. Otherwise, some other functions may not work

properly.

7.The Ni-Cd battery GB50-3FA1 is capable of saving im- portant memory registration data even at times of power failure and we suggest you replace it at least every 4 years.

8.When shipping the CCU-11B unit independently, place the mini-jumper for battery back-up in "OFF" position. Then cover CCU back with cardboard, wrap connector section in aluminium foil and put it in a con- ductive bag.

Remote Control

Replay Output

(RY1 and RY2)

PROGRAM SWITCH for No. 11 Programming

Set this in "ON" position only at time of initial pro- gramming of the exchange and registration of functions. In this case, station No. 11 is "programming station" but becomes a normal station when switch is placed in "OFF" position.

SW-B (1 ~ 6)/SW1

These switches

SW-A (1 ~ 6)/SW2

select functions.

Mini-Jumper for Battery Back-up.

Ni-Cd Battery

GB50-3FA1 (3.6V 50mAH)

— 3 —

Page 4
Image 4
Vizio manual Precautions for Installation of CCU-11B, Program Switch for No Programming