Vizio E321VL Television Antenna Connection Protection, Power Service Grounding Electrode, System

Models: E371VL E321VL

1 53
Download 53 pages 34.21 Kb
Page 7
Image 7
Television Antenna Connection Protection

Television Antenna Connection Protection

If an outside antenna/satellite dish or cable system is to be connected to the TV, make sure that the antenna or cable system is electrically grounded to provide some protection against voltage surges and static charges.

Article 810 of the National Electrical Code, ANSI/NFPSA 70, provides information with regard to proper grounding of the mast and supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of the grounding conductors, location of antenna discharge unit, connection to grounding electrodes, and requirements of the grounding electrode.



Lightning Protection

For added protection of the TV during a lightning storm or when it is left unattended or unused for long periods of time, unplug the TV from the wall outlet and disconnect the antenna or cable system.

Power Lines

Do not locate the antenna near overhead light or power circuits, or where it could fall into such power lines or circuits. Remember, the screen of the coaxial cable is intended to be connected to earth in the building installation.

Ground Clamp

Antenna Lead In Wire

Antenna Discharge Unit

(NEC Section 810-20)

Grounding Conductors

(NEC Section 810-21)

Ground Clamps

 

 

Power Service Grounding Electrode

 

 

Electric Service Equipment

 

System

 

(NEC ART 250, part H)

 

 

 

Page 7
Image 7
Vizio E321VL, E371VL Television Antenna Connection Protection, Grounding Conductors NEC Section Ground Clamps, System