INSTALLING ELECTRIC KETTLE ON COUNTER

ELECTRIC TILTING COUNTER KETTLES

INSTALLING ELECTRIC KETTLE ON COUNTER

Fig. 3 Mounting Hole Location

1.Position the kettle on the counter or stand in its final installed location with sufficient rear clearance (see Table 2 for minimum required clearance) from the wall to allow the kettle to tilt completely without obstruction. Mark the four corner locations of the kettle base as shown in Fig. 3.

2.Remove the kettle from the counter and drill four 7/16" diameter holes according to the measurements in Fig. 3.

3.Prepare a clean, dry surface according to package directions on a high grade NSF listed sealant.

4.Apply a continuous bead of sealant along the complete outer edges of the kettle base.

5.Position the kettle in place and secure firmly with supplied hardware.

6.Thoroughly wipe off excess sealant.

INSTALLATING FLOOR MOUNTED K20ETT

1.Position the kettle in its final installed location to provide drainage directly below pour path, with sufficient rear clearance (see Table 2) from the wall to allow the kettle to tilt completely without obstruction.

2.Level the kettle by making necessary adjustments using the flanged feet.

3.Mark anchoring hole locations through the flanged feet.

4.With hole location marked, drill holes to accommodate 5/16" studs.

5.Reposition the kettle.

6.Bolt the kettle down and apply a high grade NSF listed sealant around bolt heads and flange making contract with floor surface. Wipe off excess sealant immediately.

ELECTRICAL CONNECTION

Electrical and grounding

connections must comply with the applicable portions of the National Electrical code and/ or other local electrical codes.

1.Open control box.

2.Connect electric supply to terminal block.

3.See wiring diagram located inside the control box lid.

ELECTRICAL SPECIFICATIONS

TABLE 3. ELECTRICAL SPECIFICATIONS

Model

PH

208V / 240V

308V / 480V

 

 

 

 

K6ETT

1

7.5 kW-10kW

N/A

 

 

 

 

K12ETT,

1

12 kW-16kW

N/A

K20ETT

 

 

 

 

 

 

 

K6ETT

3

7.5 kW-10kW

7.5 kW

 

 

 

 

K12ETT,

3

12 kW-16kW

12 kW

K20ETT

 

 

 

Note: K6ETT and K12ETT have external terminal block. In K20ETT, terminal block is inside control box.

— 6 —

Page 6
Image 6
Vulcan-Hart K6ETT, K12ETT Installing Electric Kettle On Counter, Mounting Hole Location, INSTALLATING FLOOR MOUNTED K20ETT