MEF24A ELECTRIC FRYER REPLACEMENT PARTS
5.Remove the damaged component and install a new component in the same position.
6.Check completed circuit against circuit diagram on rear panel.
7.Mount the rear panel and put fryer in operation.
REPLACING BLOWN FUSES OR FUSE BLOCK
1.Remove four screws securing rear panel to fryer. Let rear panel fall down straight before pulling it out.
2.Remove damaged fuses and replace with 40 Ampere one time fuse.
3.To replace fuse block, remove fuses and disconnect wire leads to the damaged fuse block. Mark disconnected leads to identify them.
4.Replace new fuse block in the same position.
5.Connect leads to corresponding terminal on new fuse block. Check completed circuit against circuit diagram on rear panel.
REPLACING ELEMENT
1.Remove screws securing pivotal head cover to pivotal head. Remove pivotal head cover and gasket.
2.Lift up the elements to drain position.
3.Remove thermostat bulb and capillary tube clamps.
4.Remove element support assembly.
5.Disconnect leads to element and mark them for identification.
6.Remove the element retaining nuts inside the pivotal head.
7.Remove element. Mount the new element and reverse steps 1 through 6 to reassemble.
REPLACING HI-LIMIT THERMOSTAT
1.Remove screws securing pivotal head cover to pivotal head. Remove pivotal head cover and gasket.
2.Remove
3.Dislodge capillary bushing from hole in pivotal head.
4.Remove bushing and thread the thermostat capillary and bulb through hole in pivotal head.
5.Disconnect leads to the damaged
6.Remove screws securing the thermostat.
7.Secure new
– 10 –