WARNING: ELECTRICAL AND GROUNDING APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODES.

CONNECTIONS MUST COMPLY WITH THE ELECTRICAL CODE AND/OR OTHER LOCAL

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.

Make sure that the electrical power supply agrees with the specifications on the oven data plate, the wiring diagram on the oven and Electrical Data, page 5.

1.Wires to connect both ovens are provided with each oven. Carefully route these leads from the top oven through the bushing (supplied with the stacking kit) through the electrical access knockout holes common to both ovens.

2.Connect wires X, Y and Z from the upper oven to the lower oven per the wiring diagram using wire nuts provided. Attach the power supply conduit to the bottom of the lower oven. Connect the power supply leads to the line side of the terminal block on the bottom oven.

3.Finally, inspect and check all wiring and terminal connections for tightness or pinch points (cover on oven frame).

4.Refer to reference drawing 426986 supplied with the stacking kit for electrical connection instructions.

5.Refer to instructions supplied with the stacking kit for marking the combined electrical load information to the electrical data plate of the bottom oven.