LEG ASSEMBLY

Attach the legs to the body by threading the exposed leg stud into the threaded holes located on the underside of the unit.

Tighten each leg so that the top face of the leg is pressed firmly against the body bottom.

Do not operate griddle without legs or integrated stand as damage will occur.

LEVELING

Position the griddle in the desired location. Level the griddle by using a wrench to turn the adjustable feet. You must hold the leg while turning the foot so that it’s attachment to the griddle is not loosened.

LOCATION

The installation location must be kept free and clear of combustibles. Do not permit air to blow directly at the griddle. Avoid open windows next to the griddle wherever possible. Avoid wall-type fans which create air cross-currents within the room.

This griddle is Design Certified for installation on a non-combustible counter with 4” legs, or combustible floor with 25” high stand.

INSTALLATION CLEARANCES

 

COMBUSTIBLE CONSTRUCTION

NON-COMBUSTIBLE CONSTRUCTION

Back:

1”

0”

Right

1”

0”

Left Side

1”

0”

ELECTRICAL CONNECTIONS

Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.

Disconnect the electrical power to the griddle and follow lockout / tagout procedures.

Standard Electrical Connections

1.Remove the small cover plate on the back of the unit. This exposes the built-in junction box and griddle line leads.

2.Select a suitable knockout on the rear or bottom of the junction box.

3.Connect the griddle’s line leads to the supply wires with factory supplied wire connectors as shown in the applicable wiring diagrams.

4.Push the excess wire into the junction box and replace the cover plate. Never operate griddle without cover in place.

-3 -

Page 3
Image 3
Vulcan-Hart RRE60, RRE36, RRE24 operation manual LEG Assembly, Leveling, Location, Electrical Connections