Vulcan-Hart SCB60, SCB47 Installation, Operation And Care Of Gas Countertop Charbroilers, General

Models: SCB36 SCB30 SCB60 SCB72 SCB25 SCB47

1 8
Download 8 pages 208 b
Page 3
Image 3
INSTALLATION, OPERATION AND CARE OF

INSTALLATION, OPERATION AND CARE OF

GAS COUNTERTOP CHARBROILERS

GENERAL

Gas Countertop Charbroilers are designed for commercial use only and feature fast, efficient gas heat. Each burner is controlled by an adjustable gas valve. Cast radiants are located directly above each burner to maintain uniform temperature. Radiants are easily removed for cleaning when cool.

Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid surface to be level or sloped. Grooves, cast in the top grates, permit fat runoff and reduce flaring when tilted towards the front. A grease drawer is provided to collect fat run-off; it opens to the front for inspection or drain-off.

Model

Number of Burners

BTU/hr Input Rating

 

 

 

VCCB25, SCB25

4

58,000

 

 

 

VCCB30, SCB30

5

72,500

 

 

 

VCCB36, SCB36

6

87,000

 

 

 

VCCB47, SCB47

8

116,000

 

 

 

VCCB60, SCB60

11

159,500

 

 

 

VCCB72, SCB72

13

188,500

 

 

 

INSTALLATION

UNPACKING

Immediately after unpacking, check for possible shipping damage. If the broiler is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Before installing, verify that the type of gas (natural or propane) and the clearance dimensions (see page 4) agree with the specifications on the rating plate which is located on the lower right side.

LOCATION

The installation location must be kept free and clear of combustibles. Do not obstruct the flow of combustion and ventilation air. DO NOT install the charbroiler adjacent to open burners or fryers.

Sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system and for combustion of the gas burners. Do not obstruct the air flow into and around the appliance. Do not obstruct the flow of flue gases through and above the broiler's top grate. Position the broiler in its final location. Check that there are sufficient clearances to service the broiler and to make the required gas