TROUBLESHOOTING
Condition | Solution |
Poor contact | Clean contact parts thoroughly |
Battery voltage is | Start the engine to recharge the |
too low | battery. Replace the battery if |
| needed. |
Shutdown on | Reduce the wattage of inverter’s load |
overload |
|
Thermal shutdown | Allow the inverter to cool down by |
| reducing the load or turn it off for a |
| while. |
Receptacle has no | Check the receptacle wiring. |
power |
|
MAINTENANCE
Very little maintenance is required to keep the inverter operating properly.
DESCRIPTION
500W Peak Power — allow you to power appliances that require a large amount of initial (peak) power to work (such as many TVs and
Low Battery Alarm — the inverter sounds an audible alarm then turns itself off if the source battery becomes too low.
Auto Shutdown/Reset Protection — the inverter temporarily shuts itself down to protect itself from overheating.
Overload/Short Circuit Protection — the inverter automatically turns itself off if the connected load is too high or if it shorts.
Fuse — the inverter comes with fuse/s already installed and easily changed if it is damaged.
Dual AC Outlets — allows you to power up to two appliances at the same time.
HEAT DISPERSAL
The inverter generates heat while it is working. This is not a malfunction. However, if the inverter gets too hot while working, it will turn off by itself.
Position the inverter where air flows freely around it to allow the heat to disperse.
The inverter’s thermal protection prevents it from operating when its temperature exceeds 130 ± 10 θF / 55
± 5 θC
SPECIFICATION
Name | Description |
Input | 12V |
Output | 115V AC |
Output frequency | 60 Hz |
Output waveform | Modified Sine Waveform |
Continuous power | 175 Watt |
Surge power | 500 Watt |
Efficiency | Approx. 90 % |
No load current | < 0.2 A |
Battery low alarm | 10.5 ± 0.5 V DC |
Battery low shutdown | 10 ± 0.5 V DC |
Alarm and thermal | 130 ± 10 θF / 55 ± 5 θC |
shutdown |
|
DC fuse | 15 A |
AC output socket | 2 outlets of |
Power switch | DC input ON/OFF control |
Dimensions | 5x4.5x2 in |
Net Weight | 1 lb |
NOTE
All specifications are typical at nominal line, half load, and 25 θC unless otherwise noted. Specification subject to change without notice.
© 2003 Wagan Corporation. | 4 |
All Rights Reserved.
Wagan and Wagan.com are trademarks used by Wagan Corporation.
www.wagan.com