Elite400W Pro Pure Sine Inverter by Wagan Tech®

User’s Manual—Read before using this equipment

 

 

TROUBLESHOOTING

PROBLEM: Low or No Output Voltage – Fault LED Lit

Reason

Solution

 

 

Poor contact with battery, inverter

Clean terminals thoroughly. Reinstall

terminals, or DC socket.

and tighten. Clean DC socket with non-

 

metallic abrasive emery stick.

 

 

PROBLEM: No Output Voltage – No LEDs Lit

 

 

Reason

Solution

 

 

Blown fuse.

Check vehicle’s Accessory Socket Fuse.

 

If the fuse is blown, replace with the

 

same type and rating fuse.

 

 

PROBLEM: Inverter Auto Shut Down – Fault LED Lit

 

 

Reason

Solution

 

 

Battery voltage is below 9.5 volts.

Charge or replace battery.

 

 

Inverter is too hot (thermal shut down

Allow inverter to cool.

mode).

Check for adequate ventilation.

 

 

Reduce the load on the inverter to

 

the specified TrueRatedpower max

 

output.

 

 

PROBLEM: Inverter Shut Down – Fault LED Lit

Reason

Solution

 

 

Equipment being operated draws too

Do not use the equipment with this

much power.

inverter; use a higher wattage inverter.

 

 

PROBLEM: Continuous Buzzing Sound

 

 

 

Reason

Solution

 

 

Input voltage is below 10.5 volts .

Keep input voltage above 10.5 volts .

 

 

Poor or weak battery condition.

Recharge or replace battery.

 

 

Poor or loose cable connection.

Inspect terminals and tighten all

 

connections.

 

 

Inadequate power being delivered to

Use heavier gauge DC cables.

the inverter or excessive voltage drop.

Keep cable length as short as possible.

 

 

 

DISPOSAL/RECYCLING OF INVERTER

Electronic products are known to contain materials that are toxic if improperly disposed. Contact local authorities for disposal and recycling information.

©2012 Wagan Corporation. All Rights Reserved.

9

www.wagan.com

Wagan Tech and wagan.com are trademarks used by Wagan Corporation.

10

Page 6
Image 6
Wagan 2601 user manual Troubleshooting, DISPOSAL/RECYCLING of Inverter