Elite™ 400W Pro Pure Sine Inverter by Wagan Tech® | User’s |
|
|
FRONT PANEL
Power LED Fault LED | On/Off Switch |
AC Outlet | AC Outlet |
USB Power Port
•ON/OFF Switch — This switch controls AC output of the inverter.
•Operating LED (Green) — When this green LED is lit, the inverter is operating normally.
•FAULT LED (Red) — The RED indicator turns on as the inverter shuts down due to overheating, overload, under voltage, or over voltage.
Immediately turn off all AC appliances if the FAULT LED is lit. Allow the inverter to cool before continuing. Make sure that the ventilation vents are not blocked.
If an inverter shutdown was preceded by a buzzing sound, there may be an excessive load in combination with a low voltage or cable problem.
• AC Outlets — These outlets can supply up to 3.3 amps at 120V AC 60 Hz
•USB Power Port — This power port can supply 5 volts at 2.1A for charging or powering smartphones, tablets and
•Audible Alarm (internal to the inverter) — When the Audible Alarm makes a buzzing sound, the inverter senses a low battery condition. The user should reduce the AC load, charge the battery, and check the DC cable for excessive losses.
REAR PANEL
Postive (+) | Negative (−) |
Terminal | Terminal |
[Red] | [Black] |
| Ground |
| Terminal |
| Cooling Fan |
•Positive Terminal — Positive (+) DC Input (Red)
•Negative Terminal — Negative (−) DC Input (Black)
•Cooling Fan —
•Ground Terminal — For attaching an insulated safety ground wire. This safety wire is for protecting personnel if there is an unlikely failure in either the cabling or enclosure insulation.
©2012 Wagan Corporation. All Rights Reserved.
3
www.wagan.com
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
4