Slim Line 1750 Watt Power Inverter by Wagan Tech
USER’S MANUAL — Please read before using this equipment.
_______________________________________________________________________________________________________________________
HEAT DISPERSAL
The inverter generates heat while it is working. This is not a malfunction. However, if the inverter gets too hot while working, it will turn off by itself.
Position the inverter where air flows freely around it to allow the heat to disperse.
The inverter’s thermal protection prevents it from operating when its temperature exceeds 130 ± 10 θF / 55
± 5 θC.
SPECIFICATION
Name | Description |
Input | 12V |
Output | 1750V AC |
Output frequency | 60 Hz |
Output waveform | Modified sinewave,phase corrected |
Continuous power | 1750 Watt |
Surge power | 3500 Watt |
Efficiency | Approx. |
No load current | < 0.3 A |
Battery low alarm | 10.5 ± 0.5 V DC |
Battery low shutdown | 10 ± 0.5 V DC |
Alarm and thermal | 130 ± 10 θF / 55 ± 5 θC |
shutdown |
|
Internal DC fuse | 30 A |
External DC fuse | None |
AC output socket | 2 outlets of |
Power switch | DC input ON/OFF control |
Dimensions (LxWxH) | 15x8x3.3 in³ |
Net Weight | 10 lb |
NOTE
All specifications are typical at nominal line, half load, and 77 θF / 25 θC unless otherwise noted. Specifications are subject to change without notice.
© 2003 Wagan Corporation. | 5 |
All Rights Reserved.
Wagan and Wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
Printed in China