Cleanup - Cleaning the Suction Set

1. Lock the gun and turn the pump OFF (O).

GX-05GX-07

O

GX-08

2.Remove the suction hose and return tube and clean it using the appropriate cleaning solution. You should also wipe the threads of the inlet nut (a) and remove and clean the inlet filter of the suction tube.

(a)

3.When suction set is clean, thread the suction tube back into the inlet valve, and replace the return tube onto the return tube fitting. Replace clip.

4.Submerge the suction set into a bucket of NEW cleaning solution.

5.Turn the PRIME/SPRAY knob to PRIME. Turn the pump ON (l), and trigger the gun once into a waste container to relieve pressure.

6.Let the pump circlulate cleaning solution through the suction set for 2-3 minutes. Turn the pump OFF.

SPRAY

PRIME

l

2 to 3

minutes

IMPORTANT!

If you used oil-based materials, you must flush the pump again using water to prepare it for storage. Repeat #1 - #11 in Cleanup- Latex materials, instructions.

Move on to Cleaning the Spray Gun Components.