Before you begin - This section contains instructions that will be repeated throughout this manual.

Locking the Spray Gun:

WARNING Always lock the trigger off when attaching the spray tip or when the spray gun is not in use.

Model GX-05 and GX-07 Spray Gun

The gun is locked when the trigger lock is at a 90º angle (perpendicular to the trigger in either direction).

GX-05GX-07

Model GX-08 Spray Gun

To lock the gun, turn the trigger lock forward and slightly down until it stops.

Plugging in the Sprayer:

1.Check that the ON/OFF switch is in the OFF (O) position.

O

2.Plug the power cord into a grounded outlet or heavy duty grounded extension cord. Plug in the extension cord. Refer to Important Electrical Information, page 3.

Pressure Relief Procedure:

WARNING

Be sure to follow the Pressure Relief Procedure when shutting the unit off FOR ANY PURPOSE.

This procedure is used to relieve pressure from the spray hose.

1.Lock the spray gun off (see directions above). Move the ON/OFF switch to the OFF position.

O

2.Turn the PRIME/SPRAY knob to

PRIME.

SPRAY

PRIME

3.Unlock the spray gun and trigger spray gun into the side of the material bucket. Lock the spray gun.

7

English

 

 

Page 7
Image 7
Wagner SprayTech 9150, 9170, 9146 Locking the Spray Gun, Plugging in the Sprayer, Pressure Relief Procedure, GX-05GX-07