EDITION 07 /2005 | PART NO. DOC0350941 |
OPERATING MANUAL
GA 250AL_GA 400AL.
5.4WORK
5.4.1START-UP FOR AIRLESS SPRAYING
1.Switch on the material supply (adjust from approx. 150 bar; 15 MPa; 2175 psi), and the control unit.
2.Spray on a test object.
3.Adjust the spray pressure and atomizing air in accordance with the nozzle and object.
Note:
The paint output volume can be changed by:
•Changing the material pressure. or
•Fitting another flat jet nozzle. See accessories.
5.4.2REPLACING THE AIRLESS FLAT JET NOZZLE
1.Replace material with cleaning agent and flush the spraygun.
2.Relieve spraygun and unit pressure.
3.Secure the gun. (Remove the control air hose)
4.Unscrew the nozzle nut (E) and remove the flat jet nozzle (D).
Note:
Ensure that the seal (C) is not lost.
Mounting:
5.Insert a cleaned or new nozzle into the nozzle nut (E).
6.Insert the seal (C) into the nozzle nut.
7.Put the nozzle nut, together with the nozzle and seal, onto the gun and tighten it gently.
8.Turn the nozzle (D) so that it corresponds to the required spray pattern.
9.Tighten the nozzle nut (E).
10.Reconnect the control air hose (A).
"
!
#
$
%
"?
5.4.3CLEANING THE AIRLESS FLAT JET NOZZLE
The Airless flat jet nozzle (D) can be put into a cleaning solvent recommended by the paint manufacturer.
Attention
Do not handle the flat jet noozle with
21