Wayne GPB400 warranty Engine Driven Centrifugal Pump, Description, Safety Guidelines

Models: GPB400

1 20
Download 20 pages 52.34 Kb
Page 1
Image 1
Operating Instructions and Replacement Parts List

Operating Instructions and Replacement Parts List

GPB400

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Engine Driven

Centrifugal Pump

Description

The WAYNE pumps are general use centrifugal water pumps. The pump is equipped with EPDM seals that are intended for water use only.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates an imminently hazardous

situation which, if NOT avoided, WILL result in death or serious injury.

Warning indicates a potentially hazardous

situation which, if NOT avoided, COULD result in death or serious injury.

Caution indicates a potentially minor or

moderate injury, if NOT avoided, MAY result in serious injury.

Notice indicates important

information, that if NOT followed, MAY cause damage to equipment.

General Safety

Information

CALIFORNIA PROPOSITION 65

This product may contain chemicals

known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

1.Know the pump application, limitations, and potential hazards. Read these rules and the instructions carefully. Failure to follow them could cause serious bodily injury and/or property damage.

NEVER run engine in

an enclosed area. Exhaust gases contain deadly poisonous carbon monoxide, which has no odor or taste.

Do NOT use to pump

flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do NOT use in flammable and/or explosive atmospheres. Pump SHOULD only be used with liquids compatible with pump component materials. Failure to follow this warning CAN result in personal injury and/or property damage.

2.Observe all safety precautions for the handling of the fuel.

Do NOT refuel a hot engine. Fuel spilled on a

hot engine could result in a fire or explosion. Do NOT refuel a running engine.

3.Pump should be located and should rest on a level solid foundation. Do NOT suspend pump by means of the discharge pipe.

Be sure pump is on secure footing so it

doesn’t fall over.

4.Do NOT use torches or apply excessive heat, fire or flames to this pump as an explosion may result.

5.Before working on the unit, insulate the wire from the spark plug, by disconnecting the spark plug wire from the spark plug.

Complete pump and piping system

MUST be protected against below freezing temperature. Failure to do so COULD cause serious damage and WILL void the warranty.

6.Do NOT run pump dry. Water is required to lubricate the shaft seal.

7.Pumping chemicals or corrosive liquids with this pump will shorten the life of the pump and may be hazardous to the operator and void the warranty.

8.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment.

c.Keep visitors at a safe distance from the work area.

d.Make workshop child-proof with padlocks, master switches, and by removing starter keys.

9.This pump is designed for non-abrasive fluid transfer; do NOT use as a trash pump. ALWAYS use a suction strainer with this pump to filter abrasive material. Abrasive materials such as sand and gravel will shorten the life of the pump.

Installation

This pump is designed to be self-priming when installed and operated as specified below.

1.The pump should be placed as close as possible to the water being pumped. A pump with 20 foot suction lift will not remove water as quickly as a pump with 5 foot suction lift (Figure 1).

20 FT. SUCTION LIFT

5 Ft.

SUCTION

LIFT

Figure 1

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

© 2011, WAYNE/Scott Fetzer Company.

For parts, product & service information

320605-001 8/11

 

visit www.waynepumps.com

 

Page 1
Image 1
Wayne GPB400 warranty Engine Driven Centrifugal Pump, Description, Safety Guidelines, General Safety Information