Operating Instructions and Parts Manual |
|
|
| |
Installation and Operation | Maintenance | 3. To verify discharge hose is free from | ||
(Continued) |
| |||
3. For best pump performance, unwind | Always | a blockage. | ||
a. | Connect hose to another | |||
disconnect electric supply | ||||
the hose before starting the pump. | ||||
before attempting to install, |
| water source such as a faucet. | ||
This will help remove any kinks or |
| |||
service, relocate or perform |
| If water flows through hose, | ||
binds in the hose and allow the unit |
| |||
any maintenance. Failure to do so could |
| proceed to step 3b. If water is | ||
to pump with less restriction. |
| |||
result in fatal electrical shock. |
| restricted, verify discharge hose | ||
4. Set the pump on a hard, flat surface |
| |||
Minimal service is required for this |
| is unwound. Remove all kinks, | ||
in the water. Do not set the pump | pump. If pump should fail to operate, |
| bends or obstructions in hose. | |
directly on mud or sand surfaces. This | perform the following troubleshooting | b. | Verify pumping height does NOT | |
will cause the inlet screen to clog. | ||||
guidelines: |
| exceed 20 feet (See Figure 1). If | ||
5. The water level must be at least |
| |||
1. The motor housing of the pump is |
| pumping height is greater than 20 | ||
completely sealed and requires no |
| feet, this pump will NOT work. | ||
and operate. | service. | 4. Periodic cleaning of pump is | ||
Water levels less than | ||||
| required to maintain performance of | |||
will not allow the impeller to |
| the pump. Follow the cleaning steps | ||
contact water and no water will be | Disassembly of the motor | listed below: | ||
pumped. | housing or alteration of the | a. Unplug the power cord. | ||
| power cord could result in | |||
Do not | b. Remove the 4 screws in the | |||
fatal electrical shock. | ||||
handle | 2. To verify pump is operating correctly. |
| bottom of the base (Reference | |
pump with wet hands or |
| No. 7 in diagram on page 3). | ||
|
| |||
when standing in water or | a. Disconnect pump from power |
| ||
c. Remove the base (Reference No. | ||||
on a damp surface when the | source. | |||
| 7).and inlet plate (Reference No. | |||
unit is operating or fails to operate. | b. Disconnect discharge hose from |
| ||
Always disconnect pump power cord |
| 6) | ||
pump. |
| |||
from power source before handling. | d. Remove the debris and make | |||
| ||||
| c. Immerse pump in a bucket or tub | |||
6. Plug the power cord into a |
| sure the impeller turns freely. | ||
of water. |
| |||
grounded | e. Reinstall inlet plate, base and | |||
d. Plug power cord into a grounded | ||||
outlet. The pump will start operating | ||||
| screws. | |||
as soon as the power cord is plugged | 115 volt GFCI power outlet. If |
| ||
|
| |||
into the power outlet. | pump operates correctly proceed |
|
| |
7. The pump will remove water down | to step #3. If pump does NOT |
|
| |
operate, unplug power cord |
|
| ||
to 1/2 inch above the hard surface |
|
| ||
and proceed to maintenance |
|
| ||
the pump was placed on. |
|
| ||
guideline item 4 in this section. |
|
| ||
8. The pump should be turned off once |
|
| ||
|
|
| ||
the water level reaches the 1/2 inch |
|
|
| |
mark. |
|
| 20 Ft. Max. | |
Do not allow pump |
|
| ||
|
|
| ||
to run dry. The shaft |
|
|
| |
seal depends on water for lubrication. |
|
|
| |
Operating pump without water will |
|
|
| |
damage the shaft seal and cause pump |
|
|
| |
failure. |
|
|
| |
|
|
| Water Level | |
| Figure 1 - Water Level |
|
| |
www.waynepumps.com |
|
|
| |
| 2 |
|
|