Step 17

Connect LP tank

mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.

Hook the LP tank onto the fuel scale. Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 17.

E

Tank lock

 

wing nut

Route the hose so it will not interfere with the scale indicator rod.

The hose and regulator are connected in the following manner:

Slide back the collar of the quick disconnect on the tank valve. Push the male fitting of the regulator into the quick disconnect, and maintain pressure. Slide the collar closed. Figure 18 (a). Figure 18 (b) shows the quick disconnect engaged and various components of the tank and regulator. Regulator vent hole should be at 3, 6, or 9 o'clock. It should not be pointed up. Figure 18 (c).

F

Figure 17

(a)

Male fitting

Hose (b)

Tank valve

Regulator

Regulator vent

Collar

Valve handwheel close clockwise

Pressure relief valve

Tank

Quick disconnect engaged

(c)

Turn so regulator vent does not collect water

Figure 18