16 | OPERATING INSTRUCTIONS |
|
|
LIGHTING
Summary lighting instructions are on the control panel.
WARNING: Check hose before each use of fireplace for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the fireplace. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber. com®.
1)Remove rain shields.
DANGER
Failure to remove rain shields while igniting the
fireplace’s burners, or not waiting 5 minutes to allow the gas to clear if the fireplace does not light, may result in an explosive
2)Make sure the burner control knob is turned OFF. (Push control knob down and turn clockwise to ensure that it is in the OFF position.)
WARNING: The burner control knob must be in the OFF position before turning on the liquid propane cylinder tank valve. If it is not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP cylinder valve and burner control knob. Then start over.
DANGER:
When the “excess gas flow control” feature is activated, a small amount of gas is still flowing to the burner. After turning OFF the cylinder valve, wait at least 5 minutes for the gas to clear before attempting to light the fireplace. Failure to do so may result in an explosive
3)Turn the cylinder on by slowly turning the cylinder valve counterclockwise.
WARNING: Do not lean over the open fireplace. Keep your face and body at least one foot away from the logs when lighting the fireplace.
4)Push burner control knob in and turn
5)Push in igniter several times, until burner is lit.
6)Check that the burner is lit.
WARNING: If the burner does not light, turn the burner control knob to OFF and wait 5 minutes to let the gas clear before you try again or try to light with a match.
1. |
|
|
|
| 6. |
2. | 4. | 5. |
| ||
|
| 3. |
Note: Normal burning pattern will develop light soot on log set. If heavy sooting occurs, refer to troubleshooting.
TO EXTINGUISH
Push in the burner control knob and turn clockwise to the OFF posi- tion. Turn gas supply OFF at the source. When unit has cooled, replace rain shields.
WARNING
Inspect the burner before each use of the fireplace. If it is evident that the burner is damaged in any way, it must be replaced with a burner specified by the manu-
facturer prior to the fireplace being turned on. Failure to comply with these measures could result in an ex- plosive