Weber 425, 450 manual Maintenance, Crossover Ignition System Operations

Models: 450

1 16
Download 16 pages 7.78 Kb
Page 13
Image 13
Crossover Ignition System Operations

MAINTENANCE

11.Lift and twist the burner assembly slightly to separate the crossover tube from the burners. Remove the burners from the cooking box. Figure 14.

Separate here

Crossover tube

Figure 14

12. To reinstall the burners, reverse steps 3 through 11.

mCAUTION: The burner openings must be positioned properly over the valve orifices. Figure 15 (a).

Check proper assembly before fastening manifold in place. Figure 15 (b).

(a)

Valve

Burner

Orifice

(b)

Figure 15

Crossover Ignition System Operations

If the Crossover Ignition System fails to ignite the Left burner, light the Left burner with a match. If the Left burner lights with a match, then check the Crossover Ignition System.

Check that both the white and black ignition wires are attached properly. Figure 16.

Check that the Crossover Ignition button pushes the igniter (button) down, and returns to the up position.

Check to see if the igniter is loose in the frame. Tighten if necessary; See Step “Install igniter” for correct procedure.

If the Crossover Ignition System still fails to light, contact Weber-Stephen Customer Service.

White wire

Black wire

Figure 16

13