General Maintenance
Weber Spider Stopper Guards
Your Weber Gas Barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 9. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.
Main Burner Flame Pattern
The Weber Gas Barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown in Figure 11.
Tips occasionally yellowish
Burner inside cooking box
Venturi
Flames
Light blue
Dark blue
Figure 11
Air shutter
Venturi fin
If the flames do not appear to be uniform the length of the burner tube, follow the burner cleaning procedures.
Figure 9
The Weber Spider Stopper Guard is factory installed. It fits tightly around the air shutter section of the burner tube and the valve, thereby preventing spiders and other insects access to the burner tubes through the air shutter openings. Figure 10.
Weber Spider
Stopper Guard
Figure 10
We recommend that you inspect the Weber Spider Stopper Guards at least once a year. (See Section “Annual Maintenance”.) Also inspect and clean the Spider Stopper Guards if any of the following symptoms should ever occur.
1.The smell of gas in conjunction with the burner flames appearing yellow and lazy.
2.Barbecue does not reach temperature.
3.Barbecue heats unevenly.
4.One or more of the burners do not ignite.
Main Burner Cleaning Procedure
Turn off the gas supply. Remove the manifold. (See Section “Replacing the main burners”.)
Look inside each burner with a flashlight. Figure 12.
Figure 12
Clean the inside of the burners with a wire (a straightened out coat hanger will work). Figure 13. Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a brass bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.
Figure 13
mCAUTION: Do not enlarge the burner ports when cleaning.
mDANGER
Failure to correct these symptoms may result in a fire which can cause serious bodily injury or death and cause damage to property.
Replacing Main Burners
a)Your Weber Gas Barbecue must be OFF and cool.
b)Turn gas OFF at source.
c)Remove control panel: take off the burner control knobs. Remove the screws holding the control panel in place. Lift off the control panel.
29