Your Weber Gas Grill Manifold assembly consisting of gas manifold, valves and gas burners has been factory assembled, pressure- and flame- tested. As a safety precaution, we recommend you check the burner alignment:

1)Are the ends of the burners under the washers at the left rear and left front of the cooking box? The screws are only guides. Do not tighten.

2)Do the valves fit into the ends of the burners?

3)Are the wing nuts under the burner assembly hand tight? Do not tighten with pliers.

If you answered YES to 1, 2 and 3, the burners are correctly aligned. If you answered NO, the burners are misaligned. Contact the Customer Service Represen- tative in your region using the contact information sheet provided with your manual. Do not use grill.

(2)

(1)

(3)

Install Gas Supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installa- tions. In absence of Local Codes, you must con- firm to the latest edition of ANSI Z223.1. WE REC-

OMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifi- cations.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected

The quick disconnect fitting can be installed horizon- tally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to

rigid, permanent construction.

￿WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

 

Gas supply

Inside wall

 

Outside wall

 

 

Shut off

Quick Disconnect

Locking shut off

 

B-4

Page 14
Image 14
Weber D082.A Install Gas Supply General Specifications for Piping, Ommend That this Installation be Done by a Professional

C075.A, A103.A, B069.A, D082.A specifications

The Weber D082.A, B069.A, A103.A, and C075.A are part of Weber's distinguished range of high-performance electronic control devices, specifically designed for various industrial and commercial applications. Each model showcases distinctive features and cutting-edge technologies that enhance operational efficiency and reliability.

The Weber D082.A is renowned for its robust build, integrating advanced automation technology. It offers versatile programming options that allow users to customize operation modes based on specific applications. The D082.A supports multiple communication protocols, ensuring seamless integration with existing control systems. It is equipped with a high-resolution display for real-time monitoring and diagnostics, enabling users to make quick adjustments and enhance productivity. The protective design resists environmental challenges, making it suitable for harsh industrial settings.

Next, the B069.A model is designed with an emphasis on energy efficiency. It employs intelligent power management systems to reduce energy consumption while maintaining high output performance. This device is also equipped with advanced fault detection algorithms that quickly identify potential issues, minimizing downtime. Moreover, the B069.A features an intuitive user interface that simplifies configuration and operation, ensuring that even operators with limited technical knowledge can manage the system effectively.

The A103.A highlights its adaptability through modular design, allowing businesses to tailor the unit to their specific requirements by adding or removing components as needed. This flexibility is complemented by enhanced safety features, including emergency stop mechanisms and fail-safe operations, which ensure user protection in the event of system malfunctions. Additionally, the A103.A is designed for ease of maintenance, with quick-access panels that facilitate routine checks and service.

Finally, the C075.A model is characterized by its advanced analytics capabilities. With real-time data collection and analysis, this device enables users to optimize processes and predict maintenance needs. The C075.A incorporates state-of-the-art sensor technology, providing accurate monitoring of various parameters, including temperature, pressure, and flow rates. This information can be invaluable for industries that demand precision and compliance with regulatory standards.

In summary, the Weber D082.A, B069.A, A103.A, and C075.A collectively offer a range of advanced features and technologies aimed at improving industrial operations. Their unique characteristics cater to the diverse needs of modern enterprises, emphasizing efficiency, adaptability, and safety across various applications.