Weber S-440 GAS Supply, General Specifications for Piping, Dimensions, Silver Gold Tolerances

Models: S-440 S-640 Built-In LP Gas Grill

1 28
Download 28 pages 8.7 Kb
Page 20
Image 20

20

GAS SUPPLY

 

 

BUILT-IN GAS LINE LOCATIONS

Note: Leave an access in the “island” structure for gas supply and regulator service that is not inside the grill structure. Weber® has a gas line and regulator access door (part # 36311) available from your dealer or call Customer Service at 1-800-446-1071.

Note: Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in structure.

 

 

a

 

 

1

 

1

2

 

 

2

3

3 c

 

TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION

We recommend that this installation be done by a LICENSED professional.

GENERAL SPECIFICATIONS FOR PIPING

Note - Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.

This grill is designed to operate at 11 inches of water column pressure. An LP in line regulator may be necessary for this pressure.

CAUTION: If young children are in the area, a locking valve should be considered.

Pipe compound should be used which is resistant to the action of liquid propane gas when gas connections are made.

The gas connections must be fi rmly attached to rigid, permanent construction.

Note: The information provided in this manual is general for typical installations. We cannot cover all possible installation ideas. We recommend, prior to installation, that you contact your municipality for local building codes and your local fire department for installation verification.

If you have any questions, contact Customer Service at 1-800-446-1071.

b

DIMENSIONS

BUILT-IN GAS LINE LOCATIONS

 

SILVER

GOLD

 

TOLERANCES

 

 

 

 

 

1

3 3/4˝

3 3/4˝

 

+1/8˝(3.8mm)

 

(95.3 mm)

(95.3 mm)

 

- 1/8˝(3.8mm)

2

 

 

 

 

6 1/4˝

6 1/4˝

 

+1/8˝(3.8mm)

 

(158.8 mm)

(158.8 mm)

 

- 1/8˝(3.8mm)

3

 

 

 

 

2 1/2˝

2 1/2˝

 

+1/8˝(3.8mm)

 

(63.5 mm)

(63.5 mm)

 

- 1/8˝(3.8mm)

a

 

 

 

 

 

Plan View Left

 

 

 

 

 

 

b

 

Side View

 

c

 

Gas Inlet

 

 

 

 

 

 

Table

Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch

 

10-1

 

 

 

 

Water Column. (Based on a 0.60 Specific Gravity Gas)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal

Internal

 

 

 

 

 

 

Length of Pipe (Feet)

 

 

 

 

 

 

 

Iron Pipe

Diameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size

(Inches)

10

20

30

40

50

60

70

80

90

100

125

150

175

200

 

(Inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4

.364

32

22

18

15

14

12

11

11

10

9

8

8

7

6

 

3/8

.493

72

49

40

34

30

27

25

23

22

21

18

17

15

14

 

1/2

.622

132

92

73

63

56

50

46

43

40

38

34

31

28

26

 

3/4

.824

278

190

152

130

115

105

96

90

84

79

72

64

59

55

 

1

1.049

520

350

285

245

215

195

180

170

160

150

130

120

110

100

 

1 1/4

1.380

1050

730

590

500

440

400

370

350

320

305

275

250

225

210

 

1/12

1.160

1600

1100

890

760

670

610

560

530

490

460

410

380

350

320

 

2

2.067

3050

2100

1650

1450

1270

1150

1050

990

930

870

780

710

650

610

 

2 1/2

2.469

4800

3300

2700

2300

2000

1850

1700

1600

1500

1400

1250

1130

1050

980

 

3

3.068

8500

5900

4700

4100

3600

3250

3000

2800

2600

2500

2200

2000

1850

1700

 

4

4.026

17500

12000

9700

8300

7400

6800

6200

5800

5400

5100

4500

4100

3800

3500

 

 

 

 

 

 

 

© 1997 National Fire Protection Association, Inc. and International Approval Services - U.S., Inc. All Rights Reserved.

 

 

 

WWW.WEBER.COM®

Page 20