Weber Q220 Maintenance, Replacing Burner Tube, Ignition System Operations Q100

Models: Q220 Q100

1 32
Download 32 pages 39.44 Kb
Page 8
Image 8

8 MAINTENANCE

REPLACING BURNER TUBE

(x)

1) Your Weber® Qgrill must be OFF and cool.

2) Unscrew and remove propane cylinder from the valve/regulator assembly.

3) Open the lid.

4) Remove cooking grate.

5) Remove the 1/4 X 20 inch screw that holds the burner tube to the cookbox (x).

6) Carefully slide the burner tube out from the cook box.

Caution: The burner opening(1) must be positioned properly over the valve orifices(2).

7)To reinstall the burner, reverse 5) through 7).

Make sure the igniter port hole (B) lines up with the arrow tab (C) on the igniter box.

IGNITION SYSTEM OPERATIONS (Q100, 200)

If the ignition system fails to ignite the burner, light the burner with a match. If the burner lights with a match, then check the ignition system.

Check that both the white(1) and black(2) ignition wires are attached properly.

Check that the ignition button pushes the igniter (button) down, and returns to the up position.

If the ignition system still fails to light, Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

1.

2.

ELECTRONIC IGNITION SYSTEM OPERATIONS (Q120, 220)

If the electronic ignition system fails to ignite the burner, light the burner with a match. If the burner lights with a match, then check the Electronic Ignition System.

Check that both of the ignition wires are attached properly to the igniter electrodes

(1) on the ignition module.

Check that the Electronic Ignition Button is working by listening and looking for sparks at the burner.

REPLACE BATTERY IF NECESSARY

AAA alkaline battery only. See illustration:

If the Electronic Ignition System still fails to light, contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

Page 8
Image 8
Weber Maintenance, Replacing Burner Tube, Ignition System Operations Q100, Electronic Ignition System Operations Q120