31
SIDE BURNER TROUBLESHOOTING
PROBLEM CHECK CURE
Side Burner does not light. Is gas supply off?
The excess fl ow safety device,
which is part of the barbecue to
cylinder connection, may have
activated.
Turn supply on.
To reset the excess fl ow safety device turn all burner control
knobs and the cylinder valve OFF. Disconnect the regulator
from the cylinder. Turn burner control knobs to HIGH. Wait at
least 1 minute. Turn burner control knobs OFF. Reconnect the
regulator to the cylinder. Turn cylinder valve on slowly. Refer to
“Lighting Instructions”.
Flame is low in HIGH position Is the fuel hose bent or kinked? Straighten hose.
Push button ignition does not
work.
Does burner light with a match? If match lights burner, check igniter (see below).
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area
using the contact information on our web site. Log onto www.weber.com®.
Side Burner Grate
Side Burner Cap
Side Burner Ring & Head
Igniter Electrode
Control Knob

SIDE BURNER MAINTENANCE

WARNING: All gas controls and supply valves should

be in the OFF position.

Make sure wire is connected between the igniter and electrode
(1). Spark should be a white/blue color, not yellow.
1) Igniter Wire
2) Burner

(1)

(2)