Page 3
B. INSTALL THE RF SWITCH
See Figure 1 (Page 5) and Figure 2 (Page 5) of this guide for views of the module and its installation.
1.Remove the
2.From the inside of the unit, install the RF Switch into position. The “F” Connectors should protrude through the rear panel
3.Install one (1)
4.Line up the two holes in the rear of the RF Switch Bracket with the holes mentioned in Step # B1. Insert the
5.Tighten the Screw inserted in Step # B3 at this time. Do not overtighten.
6.Connect the supplied
7.On most units, the motherboard connector will be labeled “RF Switch Expansion Bus” or “Relay Expansion Bus,” and should have a number beside it corresponding to the number in the following table. See Table 1, below, for the various models. Make sure Pin 1 (the Red Line) on each cable connector goes to Pin 1 on each board connector. If you have any questions about this, contact system network control or Wegener Customer Service at
Table 1. Receiver Models and RF Switch Expansion Bus Connector Numbers
Receiver Model | Connector Number |
|
|
|
|
UNITY401R | J7 |
|
|
UNITY500 | J11 |
|
|
UNITY4000 | J11 |
|
|
UNITY4422 | J16 |
|
|
UNITY5000 | J49 |
|
|