Weil-McLain CG10, CG25, CG50 manual Burner specifications and settings, Burner data

Models: CG10 CG50 CG25

1 4
Download 4 pages 36.44 Kb
Page 2
Image 2
Burner specifications and settings

Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners

Burner specifications and settings

Table 1

Burner data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

Burner

Burner

Beckett

Approximate

Starting

Positive

Burner

Pressure

Gas

Gas Pressure

Model

Input

Model

Burner

Starting

Head

Pressure In

Motor

Drop

Manifold

Required At

Number

Gas

Number

Part Number

Air Settings

Setting

Firebox

3450 Rpm

Through

Pressure

Gas Controls

 

Mbh

 

For Ordering

 

 

 

Inches W.C.

H.P.

Gas Train

(High

 

Inlet

 

 

 

 

 

 

 

 

 

Inches W.C.

Fire)

Inches W.C.*

 

 

 

 

 

 

 

 

 

 

Inches

 

 

 

 

 

 

 

Low

High

 

 

 

 

Min

 

Max

 

 

 

 

 

 

 

 

W.C.

 

 

 

 

 

Fire

Fire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

488R

996

CG10

CG106152

N/A

10/3.5

6

0.50

1/3

2.46

4.30

6.71

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

488

1010

CG10

CG106152

N/A

10/3.5

6

0.50

1/3

2.53

4.50

6.71

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

588

1357

CG25

CG251258

23

39

1

0.60

3/4

1.90

3.55

5.50

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

688

1703

CG25

CG252259

25

48

2

0.70

3/4

2.45

3.70

6.57

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

788

2049

CG50

CG501289

14

28

1

0.60

2

2.14

3.10

5.11

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

888

2396

CG50

CG502290

14

31

2

0.65

2

2.57

3.05

5.62

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

988R

2482

CG50

CG502291

14

34

2

0.60

2

2.44

3.10

5.50

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

988

2713

CG50

CG502291

14

34

2

0.60

2

2.92

3.75

5.50

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1088R

2887

CG50

CG503292

17

38

3

0.65

2

1.94

3.00

6.00

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1088

3103

CG50

CG503292

17

38

3

0.65

2

2.25

3.65

6.00

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1188

3392

CG50

CG504293

20

50

4

0.70

2

2.65

3.60

6.45

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1288

3753

CG50

CG504294

19

68

4

0.65

2

3.25

4.15

6.36

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1388

4113

CG50

CG505295

24

93

5

0.70

2

2.53

4.00

6.68

 

14.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Gas pressures shown are for standard gas train arrangement. Contact Weil-McLain for alternate gas trains to support other gas pressures.