 THERMA TRIM

MODEL TT HYDRONIC BASEBOARDPosition back panelsMin 3 ¾"Max 4 ½"Butt back panels together.Hinged THERMA TRIM

MODEL TT HYDRONIC BASEBOARD

ASSEMBLY INSTRUCTIONS

Position back panels

Back panels must be positioned correctly to accommodate accessories, as shown below.

Min 3 ¾"

Min 1Z\v"

Max 4 ½"

Max 1>zn"

Min 3"

Min 0"

Max 3Z\v"

Max 2 Zx "

Butt back panels together.
HingedInsideSpliceOutsideInsidePlain end cap
end capbay corner

 

cornercorneror wall end
Attach back panel to wall

Screw or nail into wall studs at top and bottom.

No closer than 3 inches from end of panel.

Bottom of panel must never be lower than the surface of the finished floor or carpet.

Add shim as shown if necessary.

Shim (if needed)

Finished floor surface or carpeting.

Install brackets

Position brackets evenly along length of panel, approximately every 2 feet.

aInsert top bracket tab into top slot in back panel.

bPress bracket flat against back panel and slide down so bottom tab enters bottom slot in back panel.

Cut element

When a shorter length is needed

a

Measure from the

New

female end for the

length

required length.

b

Cut glide rails with

 

tin snips.

c

Remove 6 fins on

 

each side of the

 

location to be cut.

d

Cut copper using

New

tube cutter and

length

ream to remove

 

 

burrs.

550-110-762/0400