Wells-Gardner Electronics Corporation

TIMING CHART:

5 Standard Factory Pre-Set Timing Modes.

Can be set to any customer requirement of 15.75-40Khz hor and 40-100Hz vert.

 

 

Timing shown is based on 801GC/GX signal generator

 

 

 

 

 

CGA

MID-

RES

Mode 3

Mode4

 

Mode 5

HORIZONTAL

640X240

773X384

640X480

720X400

800X600

 

 

 

 

 

 

 

VGA_M3 VGA_2

VG900602

Scan freq.

15.725kH

24.394kHz

31.469kHz

31.469Khz

37.879KHz

scan per.

63.594us

41.00us

31.777us

31.777us

26.00us

sync pulse

4.688us

3.00us

 

3.813us

3.813us

3.200us

front porch

2.187us

2.910us

0.636us

0.636us

1.000us

active vid.

50.00us

30.690us

25.422us

25.422us

20.000us

back porch

6.719us

4.440us

1.906us

1.906us

2.200us

sync polarity

(

-

)

(

-

)

(

-

)

(

-

)

(

+

)

VERTICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vert. scan freq.

60.018Hz

57.534Hz

59.941Hz

70.087Hz

60.317Hz

scan per.

16.662ms

17.384m

16.683ms

14.268ms

16.579ms

sync pulse

0.191ms

0.164ms

0.064ms

0.064ms

0.106ms

front porch

0.190ms

0.451ms

0.318ms

0.318ms

0.02ms

active vid.

15.263ms

15.621ms

15.253ms

12.711ms

15.840ms

back porch

1.018ms

1.148ms

1.048ms

1.048ms

0.607ms

sync polarity

(

-

)

(

-

)

(

-

)

(

+

)

(

+

)

Lee

Page 9
Image 9