Wells HC-1256, HC-2256 operation manual Troubleshooting, Symptom, Possible Cause, Suggested Remedy

Models: HC-1006, HC-1256, HC2256 HC-1256 HC-2256

1 12
Download 12 pages 20.24 Kb
Page 10
Image 10
TROUBLESHOOTING

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

Hotplate won’t heat

Disconnect turned OFF or circuit

Turn disconnect ON

 

breaker tripped

Check / reset circuit breaker

 

 

 

One or more sections

Temperature control not on

Turn temperature control to

won’t heat

 

desired setting

 

 

 

 

Damaged temperature control,

Contact Authorized Wells

 

element or other internal component

Service Agency for repairs

 

 

 

Hotplate not hot enough

Temperature control not set

Adjust for desired temperature

 

 

 

 

Operating 208/240V unit at 120V

Be sure supply voltage

 

 

matches nameplate voltage

 

 

 

 

Damaged temperature control,

Contact Authorized Wells

 

element or other internal component

Service Agency for repairs

 

 

 

Hot surface indicator does

Damaged temperature control,

Contact Authorized Wells

not light, or stays on

element or other internal component

Service Agency for repairs

 

 

 

NOTE: There are no user serviceable components in the hotplate. In all cases of damage or component malfunction, contact your Authorized Wells Service Agency for repairs.

8

Page 10
Image 10
Wells HC-2256, HC-1006, HC-1256, HC2256 operation manual Troubleshooting, Symptom, Possible Cause, Suggested Remedy