Wells HT-527, HT-200 Troubleshooting Suggestions, Symptom Possible Cause Suggested Remedy

Models: HT-200 HT-527

1 14
Download 14 pages 16.92 Kb
Page 12
Image 12

TROUBLESHOOTING SUGGESTIONS

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

Circuit breaker off or tripped

Reset circuit breaker

No power to warmer

 

 

Unit not plugged in

Make sure unit is plugged in to

 

 

 

power receptacle

 

 

 

 

Temperature control not set

Set control to desired temperature

Warmer will not heat

 

 

Internal damage

Contact you Authorized Wells

 

 

 

Service Agency for repairs

 

 

 

 

Water supply not turned on

Turn on water supply

Autofill does not add water to

 

 

warmer

Internal damage

Contact your Authorized Wells

 

 

Service Agency for repairs

 

 

 

 

Scale build-up on water level

Clean water level probe with delime

Warmer overflows (Autofill does

probe

cleaner

 

 

not shut off water fill)

Internal damage

Contact your Authorized Wells

 

 

Service Agency for repairs

 

 

 

 

Tank leaking or other internal

Contact your Authorized Wells

Warmer trips circuit breaker

damage

Service Agency for repairs

 

 

Internal damage

Contact your Authorized Wells

 

 

 

Service Agency for repairs

 

 

 

 

Mineral deposits on tank acting

Clean tank with delime cleaner

 

as a insulator

 

 

 

 

Warmer slow to heat

Connected to wrong voltage

Verify supply voltage - must match

 

voltage on warmer nameplate

 

 

 

 

 

 

Too much water

Remove water from pan until 1” of

 

 

water remains in tank

 

 

 

There are no user-serviceable components in this appliance.

In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.

021 303333 OpManual for Built-In Bain Marie Warmers