TROUBLESHOOTING SUGGESTIONS
SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY | |
|
|
| |
| Circuit breaker off or tripped | Reset circuit breaker | |
No power to warmer |
|
| |
Unit not plugged in | Make sure unit is plugged in to | ||
| |||
|
| power receptacle | |
|
|
| |
| Temperature control not set | Set control to desired temperature | |
Warmer will not heat |
|
| |
Internal damage | Contact you Authorized Wells | ||
| |||
|
| Service Agency for repairs | |
|
|
| |
| Water supply not turned on | Turn on water supply | |
Autofill does not add water to |
|
| |
warmer | Internal damage | Contact your Authorized Wells | |
|
| Service Agency for repairs | |
|
|
| |
| Scale | Clean water level probe with delime | |
Warmer overflows (Autofill does | probe | cleaner | |
|
| ||
not shut off water fill) | Internal damage | Contact your Authorized Wells | |
|
| Service Agency for repairs | |
|
|
| |
| Tank leaking or other internal | Contact your Authorized Wells | |
Warmer trips circuit breaker | damage | Service Agency for repairs | |
|
| ||
Internal damage | Contact your Authorized Wells | ||
| |||
|
| Service Agency for repairs | |
|
|
| |
| Mineral deposits on tank acting | Clean tank with delime cleaner | |
| as a insulator |
| |
|
|
| |
Warmer slow to heat | Connected to wrong voltage | Verify supply voltage - must match | |
| voltage on warmer nameplate | ||
|
| ||
|
|
| |
| Too much water | Remove water from pan until 1” of | |
|
| water remains in tank | |
|
|
|
There are no
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
021 303333 OpManual for Built-In Bain Marie Warmers